Measurements - electrical and non-electrical parameters and diagnostics
The frequency, voltage and temperature calibration are traceable to national standards.
We offer:
Certification:
- SZ 201 EZÚ (Cooperation Agreement)
- Czech Testing Laboratories Association, Registration Number 068
- EuroLab CZ
Customers: particularly manufacturers of electronic components, parts and devices as well as suppliers/manufacturers of parts and devices for automotive and medical engineering industries.
The organization and Test Laboratory procedures comply with the provisions of the European Standard ČSN EN ISO / IEC 17 025 - General requirements for the competence of testing and calibration laboratories.
Test - life-time, solderability, dielectric strength and insulation
Life-time tests are aimed at verifying the capability of tested product to satisfy the requested properties under test conditions for a specified time interval. Options include:
- Long-term (up to 10,000 hours) tests of product life-time under temperature and electrical load (A.C. or D.C.).
- Product parameter measurements at specified time intervals and their continuous evaluation.
- Monitoring of set test parameters.
Solderability tests of component leads by wetting balance method & resistance to soldering heat. The test determines the solderability of leads of components and their resistance to soldering heat.
Dielectric Strength and Insulation Tests. Resistance of dielectrics to electrical breakdown or test voltage flashover is monitored as well as possible dependence on test voltage polarity and/or distortion of the result at repeated application of test voltage.
We offer:
Standards:
ČSN EN 61048, ČSN EN 61049, ČSN EN 60 252
ČSN EN 60 068-2-54, ČSN EN 60 068-2-20, IEC 60-1
Certification:
- SZ 201 EZÚ (Cooperation Agreement)
- Czech Testing Laboratories Association, Registration Number 068
- EuroLab CZ
Customers: particularly manufacturers of electronic components, parts and devices as well as suppliers/manufacturers of parts/devices for automotive and medical engineering industries.
The organization and Test Laboratory procedures comply with the provisions of the European Standard ČSN EN ISO / IEC 17 025 - General requirements for the competence of testing and calibration laboratories.
Test - environmental and corrosion endurance
The purpose of the environmental testing is to verify product / part / device endurance to be stored and transported under conditions of high or low temperature, humidity, air pressure and resistance to rapid changes of ambient temperature.
Life-time tests can also be undertaken in the specified environment with an option of electrical load.
Corrosion tests compare the endurance of products / parts / devices of similar design / make to the effect of salt spray and to detect the manifestation of salt corrosion on metals, their alloys, metallic & organic coatings as well as the degradation of non-metallic parts.
We offer:
Standards:
ČSN EN 60 068-2-78, ČSN EN 60 068-2-14, ČSN EN 60 068-2-52, ČSN EN 60 068-2-67
ČSN EN ISO 9227, ČSN EN 60 068-2-13, ČSN EN 34 5791-2-11
Certification:
- SZ 201 EZÚ (Cooperation Agreement)
- Czech Testing Laboratories Association, Registration Number 068
- EuroLab CZ
Customers: particularly manufacturers of electronic components, parts and devices as well as suppliers/manufacturers of parts and devices for automotive and medical engineering industries.
The organization and Test Laboratory procedures comply with the provisions of the European Standard ČSN EN ISO / IEC 17 025 - General requirements for the competence of testing and calibration laboratories.
Test - mechanical resistance
Test determine product / part / component resistance to the effects of vibration or repeated impact to detect their weak points or degradation. Tests can also be simulated for unpacked product to determine te results of spontaneous falls.
We offer:
Standards:
ČSN EN 60 068-2-6, ČSN EN 60 068-2-29, ČSN EN 60 068-2-31
Certification:
- SZ 201 from EZÚ (Cooperation Agreement)
- Czech Testing Laboratories Association, Registration Number 068
- EuroLab CZ
Customers: particularly manufacturers of electronic components, parts and devices, suppliers and manufacturers of parts and devices for automotive industry and for medical engineering
The organization and Test Laboratory procedures comply with the provisions of the European Standard ČSN EN ISO/IEC 17 025 - General requirements for the competence of testing and calibration laboratories.
Calibration of electrical and non-electrical variables
Calibration of length gauges (slide calipers, dial indicators), for this purpose the laboratory is equipped with an Etalon set of standard gauge blocks S 30014 (Range: 0 - 100 mm).
A.C. and D.C. voltage calibration (up to 1000V)
A.C. and D.C. current calibration (10A maximum)
Calibration of ohmic resistance
Meter / Etalon: Multi-function calibrator MEATEST M-120X
Calibration of frequency/period
Meter / Etalon: Universal Counter BM 520
Calibration of RLCG meters
Meter / Etalon: RLCG Bridge HP 4274
Calibration of thermometers and humidity meters
Meter / Etalon: Digital Thermometer/ Humidity Meter TESTO 650
All test / calibration equipment is calibrated against reference / transfer standards in accordance with the calibration schedule and traceable to national standards.
The organization and Test Laboratory procedures comply with the provisions of the European Standard ČSN EN ISO/IEC 17 025 - General requirements for the competence of testing and calibration laboratories.